This project is a new pipeline that attaches two existing clearwells to an additional new clearwell. It consists of approximately 1800 lineal feet of 86 3/4″ O.D. spiral welded steel pipe at 1/2″ thickness except at valves where pipe wall thickness was required to be at 1″ thick for a minimum distance of 7′-2″ on either side of the valves.

Pipe was coated with AWWA C222 polyurethane at a minimum thickness of 25 mils and lined with AWWA C205 Cement Mortar at a thickness of 1/2″.  Both the polyurethane and cement mortar was applied in house.

All materials in contact with water are certified to NSF-61 standards for potable drinking water.

The project contained the following:

(14) Flexible couplings with AWWA M11 Harness Restraints
(19) AWWA C207 Class ‘E’ Flange connections
(65) Bell and Spigot Lap Welds
(1) 86 3/4″ O.D. x  57 1/8″ O.D. Eccentric Reducer 10′-0″ long
(1) 86 3/4″ O.D. x 62 3/4″ O.D. Eccentric Reducer 4′-0″ long
(5) 86 3/4″ O.D. size on size tees
(4) 86 3/4″ O.D. Dished Heads
(17) 86 3/4″ O.D. Multi section mitered elbows

Standards followed:

AWWA C200
AWWA C205
AWWA C207
AWWA C208
AWWA C210
AWWA C219
AWWA C220
M11 (Latest Edition)

Award Name

Pipeline Project

Company Name

Mid America Pipe Fabricating & Supply, LLC

Award Year

2022

Product Details

  • Wyckoff WTP Clearwell #3
  • Cobb County - Marietta Water Authority
  • Acworth, GA

Date Completed

December 1, 2022

Construction Standard

AWWA C200

Diameter

86 3/4"

Steel Tonnage Used

420

Steel Thickness

1/2" & 1"

Steel Fitting Type

AWWA C208 / M11